Post Info TOPIC: 1/2" hose with a Delavan 5850


Approved Exterior Cleaner

Status: Offline
Posts: 465
Date:
1/2" hose with a Delavan 5850
Permalink  
 


I switched from a 5/8" to 1/2" ID braided hose this year. I seem to have lost a small amount of distance and I'm pretty sure it's the inside diameter of the hose but I also added 25 addition feet. I used to run with 200' now I have 225. (no couplers in between). Anyone who uses 1/2" ID hose, I was just looking to see what pump your using and what kind of distance.



-- Edited by Ray W on Wednesday 18th of September 2013 02:13:07 PM

__________________



 



Approved Exterior Cleaner

Status: Offline
Posts: 1851
Date:
Permalink  
 

I have always used 1/2 inch hose and use the 5850. I have 200'of line but have an additional seperate 60'that i can add on if needed. When things get tough...distance from take and height on the ladder the fatboy has never let me down. If your using 12v delvans you need a fatboy for two reasons. Distance and incase the 5850 breaks down on you. The fatboy can do the work of the 5850 and also give you extra when needed...granted you use more solution with the fatboy. If I was just starting out I would get a fatboy first for those reasons alone.



-- Edited by Patrick G on Wednesday 18th of September 2013 06:50:35 PM

__________________

http://www.CharliesRoofCleaning.com

http://www.RoofCleaningCo.com/

Serving Long Island, N.Y.

Bayport N.Y.

631-433-6449



PWS Vender

Status: Offline
Posts: 1770
Date:
Permalink  
 

We never use a 1/2 inch always a 5/8. I think bigger is always better.



-- Edited by Roof Cleaning PA on Monday 24th of November 2014 08:55:11 AM

__________________

Eric Seitz

Liberty SoftWash

(717) 324-4208

Roof Cleaner near York PA

Pressure Washer PA

Power Washing Equipment



Approved Exterior Cleaner

Status: Offline
Posts: 5165
Date:
Permalink  
 

I use the 1/2' Kuri with a 5850. Works fine for me. I may upgrade this winter

__________________

            clean rite logo (3).jpg

                          Suffolk County Long Island New York

                     Power Washing and Roof Cleaning Long Island

                                          Clean Rite Blog

 

 

 

                  

                    

              

 



Approved Exterior Cleaner

Status: Offline
Posts: 59
Date:
Permalink  
 

I ditched the heavy 5/8" hose two seasons ago. I'm currently running a 5850 with 1/2" kuri tec. With a 3/4" feed line and 300' of 1/2" hose, I'm getting 39' of distance.

__________________

Maryland Roof Cleaning

Maryland Roof Cleaning    Delaware Roof Cleaning



Approved Exterior Cleaner

Status: Offline
Posts: 918
Date:
Permalink  
 

We use 200' of 1/2" through a 5850. I had a 5850 last me 2 years. Some have crapped out after 5 minutes.

__________________

Thompson Roof Cleaning and Power Washing LLC

Full Service Soft-Wash Experts

www.ThompsonPowerwashing.com

(877) 420-WASH

New Jersey

 



Approved Exterior Cleaner

Status: Offline
Posts: 723
Date:
Permalink  
 

5850 with 250 feet of 1/2" kuri tech, Works great. About 39 feet. I like my fatboy too. I got a diaphragm pump (one that Chris recommended) to try it out. It's fine but only went 35 feet.

__________________

PX LOGO

PacificExterior.com

San Mateo, Santa Clara, Santa Cruz & Monterey Counties

 Office: (831) 275-1296   Cell (831) 212-1341

OUR HOMEPAGE VIDEO



Approved Exterior Cleaner

Status: Offline
Posts: 191
Date:
Permalink  
 

300' of 1/2" poly braid hose using the Flojet Pentaflex pump. I get roughly 40' of distance if I need it spraying with 0020, my main nozzle is 1520. No cycling issues with the Pentaflex and I am not using the accumulator tank.

__________________

Barry Landis

Landis Roof Cleaning

Eastern Pa

610-689-4475

LandisRoofCleaning.com



Approved Exterior Cleaner

Status: Offline
Posts: 1037
Date:
Permalink  
 

I run 200 ft of 1/2 on a Fatboy with accumulator tank and I get approx 35 ft

I also have 200ft  of 1/2 on a 3/8 allflo and it gets approx 40 ft



__________________

Brian C Jackson

35 Dodge Road

Pelham ,New Hampshire 03076

http://www.jacksoncontracting.net/roof-cleaning.html

(603)401-8408 

 



Member

Status: Offline
Posts: 3
Date:
Permalink  
 

Barry Landis wrote:

300' of 1/2" poly braid hose using the Flojet Pentaflex pump. I get roughly 40' of distance if I need it spraying with 0020, my main nozzle is 1520. No cycling issues with the Pentaflex and I am not using the accumulator tank.


 Barry  how long have you been using that Pentaflex, i run Fatboys and 5850 and use 3/4 hose, i will drop down to 5/8 when I wear this hose out, but curious how how that pentaflex is holding up



__________________

David Hill

Elite Property Maintenance



Approved Exterior Cleaner

Status: Offline
Posts: 191
Date:
Permalink  
 

David - I have been using the Pentaflex five days a week since March with no issues or problems. I use it as my main spray pump and transfer pump, so it's getting quite a bit of use. We do rinse after every job all the time, so I'm sure that helps tremendously. I have always used the Fat Boys but I like the Pentaflex better because I can reduce the tip size without any worries of cycling or burning up the pump.



__________________

Barry Landis

Landis Roof Cleaning

Eastern Pa

610-689-4475

LandisRoofCleaning.com



Approved Exterior Cleaner

Status: Offline
Posts: 501
Date:
Permalink  
 

Awesome getting 39-40' with 5850. I started out with fatboys. I was disappointed with something always failing. I went with air pumps. Good pressure, heavy hose.
I may have more volume but I doubt I beat those distances.
Are all 5850 the same GPM or do they vary?

__________________

ALABAMA PRO WASH    

http://www.roofcleaningalabama.com/

Andy Hinson       

Tuscaloosa, AL. 

http://www.facebook.com/AlabamaProWash

Email: andy@alabamaprowash.com

205-799-9069

 



Approved Exterior Cleaner

Status: Offline
Posts: 146
Date:
Permalink  
 

Barry Landis wrote:

300' of 1/2" poly braid hose using the Flojet Pentaflex pump. I get roughly 40' of distance if I need it spraying with 0020, my main nozzle is 1520. No cycling issues with the Pentaflex and I am not using the accumulator tank.


 Agreed, we use 1/2 with pentaflex as well with #20 tips. We get 40' with low wind. However we are using telescoping poles now with SoftWash Systems WFP Guns and getting as high and as long as we want.

http://www.jracenstein.com/item/150-0951/softwash-waterfed-pole-gun-adapter/default.asp?sort=wz5fo

Hope this helps.

AC



__________________
Check Out The Family Of SoftWash Systems  Chemicals On Facebook!





Approved Exterior Cleaner

Status: Offline
Posts: 760
Date:
Permalink  
 

I got the new dual pump from powerwash store. I really like it compared to the homemade setup I had before.

__________________

Affordable and Safe Soft Washing,

Roof Cleaning Service in Maryland,

PG county Maryland | Southern Maryland

 



Approved Exterior Cleaner

Status: Offline
Posts: 501
Date:
Permalink  
 

Good Videos. poles are hard on the shoulders. What is the recomended length pole?

__________________

ALABAMA PRO WASH    

http://www.roofcleaningalabama.com/

Andy Hinson       

Tuscaloosa, AL. 

http://www.facebook.com/AlabamaProWash

Email: andy@alabamaprowash.com

205-799-9069

 



Approved Exterior Cleaner

Status: Offline
Posts: 146
Date:
Permalink  
 

Game Chaser wrote:

Good Videos. poles are hard on the shoulders. What is the recomended length pole?


 That Unger pole is 27 feet and weighs 4 lbs.

AC



__________________
Check Out The Family Of SoftWash Systems  Chemicals On Facebook!





Approved Exterior Cleaner

Status: Offline
Posts: 501
Date:
Permalink  
 

OK. Thanks

__________________

ALABAMA PRO WASH    

http://www.roofcleaningalabama.com/

Andy Hinson       

Tuscaloosa, AL. 

http://www.facebook.com/AlabamaProWash

Email: andy@alabamaprowash.com

205-799-9069

 



Approved Exterior Cleaner

Status: Offline
Posts: 501
Date:
Permalink  
 

Brian C Jackson wrote:

I run 200 ft of 1/2 on a Fatboy with accumulator tank and I get approx 35 ft

I also have 200ft  of 1/2 on a 3/8 allflo and it gets approx 40 ft


 What is the GPM of the flojet?



__________________

ALABAMA PRO WASH    

http://www.roofcleaningalabama.com/

Andy Hinson       

Tuscaloosa, AL. 

http://www.facebook.com/AlabamaProWash

Email: andy@alabamaprowash.com

205-799-9069

 



Approved Exterior Cleaner

Status: Offline
Posts: 146
Date:
Permalink  
 

Game Chaser wrote:
Brian C Jackson wrote:

I run 200 ft of 1/2 on a Fatboy with accumulator tank and I get approx 35 ft

I also have 200ft  of 1/2 on a 3/8 allflo and it gets approx 40 ft


 What is the GPM of the flojet?


 7 gpm at 80 psi. However they have discontinued making them and ONLY make them for us to keep our production going. If you see any out there BUY THEM UP! They will not make them anymore after they finish production on the new SoftWash Systems pump.

AC



__________________
Check Out The Family Of SoftWash Systems  Chemicals On Facebook!





Approved Exterior Cleaner

Status: Offline
Posts: 5165
Date:
Permalink  
 

Just bumping this up it was a good thread.

__________________

            clean rite logo (3).jpg

                          Suffolk County Long Island New York

                     Power Washing and Roof Cleaning Long Island

                                          Clean Rite Blog

 

 

 

                  

                    

              

 



Retired Member

Status: Offline
Posts: 790
Date:
Permalink  
 

We currently use 200' of 1/2" wit a 5850 Fatboy.

__________________

Dave Otey

 Advantage Roof Cleaning Company

Certified Roof Cleaning Specialist

630-730-8105

Aurora, IL

 

Exterior soft wash cleaning, siding, roof cleaning and cedar shake cleaning 

 



Approved Exterior Cleaner

Status: Offline
Posts: 230
Date:
Permalink  
 

I don't think you need to run out and buy them up if you see them. Lots of vendors have them. I talked with one supplier and they said they have not been told that they can no longer get them. They sell lots of them for the agriculture ie: pesticide spraying companies.

__________________

Kleen Roof & Exterior

616-914-9064

Michigan's Premier Roof Cleaning

Pressure Washing Michigan

Michigan Cedar Roof Pro

Dave Dykstra



Approved Exterior Cleaner

Status: Offline
Posts: 5165
Date:
Permalink  
 

http://www.dultmeier.com/products/search/7493



__________________

            clean rite logo (3).jpg

                          Suffolk County Long Island New York

                     Power Washing and Roof Cleaning Long Island

                                          Clean Rite Blog

 

 

 

                  

                    

              

 



Approved Exterior Cleaner

Status: Offline
Posts: 1224
Date:
Permalink  
 

 Old posting but...

While a pole of 27 ft may only be 4 lbs, leverage will make it feel heavier. You can get past this problem by counter weighting the butt end. Makes a world of a difference. 



__________________

Maverick Contracting

Long Island, N.Y.



Approved Exterior Cleaner

Status: Offline
Posts: 1337
Date:
Permalink  
 

Art these pumps just can't handle the sh use. I killed three of these in less than 6 months.

__________________

Diamond logo

Diamond Roof Cleaning and Power Washing in South New Jersey

278 Pinedge dr 

West Berlin NJ 08091

Michael De Rose-Owner

Cell-609-929-5812

 

 
 


Exterior Cleaner

Status: Offline
Posts: 92
Date:
Permalink  
 

We used 200' of 1/2" Kuri tech with a Yamada kynar/teflon AODD pump. Got about 50' distance. Next year the Yamada will be a transfer pump and for small rinse downs. Major upgrade for next year, 1" Hastelloy AODD pump w-5/8 Kuri light weight hose. (This pump was a special purchase deal (the cost of 2 FB), will NEVER need rinsing and will last for years and years). Plus I can run it from a trickle up to full flow, about 30-35 gpm without having to worry about burning anything up. Should be between 60' & 70' distance. We have a lot of steep pitched roofs up here and a lot of very tall churches.



-- Edited by ReNew Roof and Exterior cleaning on Saturday 20th of December 2014 07:26:16 AM



-- Edited by ReNew Roof and Exterior cleaning on Saturday 20th of December 2014 07:30:51 AM

__________________

ReNew Roof and Exterior Cleaning

www.streakyroof.com

Gene Perkins

Charlestown NH

603-477-5562



Approved Exterior Cleaner

Status: Offline
Posts: 3107
Date:
Permalink  
 

From day one I have been using the Fat Boy. I was pretty happy with it and after a few problems with the switch I always discarded it and added a solenoid. When the last Fat Boy started to act up Barry suggested the Flojet Pentaflex. I used it all summer with 250' 1/2" poly braided hose. We use to use 5/8, but changed two years ago and found there was little to no loss with distance. The pump has a 1/2" inlet and outlet. If the pump had 5/8" or 3/4" I think I would still stay with the easier to use and lighter 1/2" poly braided hose. I'm sure my next pump purchase will be a Pentaflex. The Fat Boys lasted about two seasons because they get rinsed with no less than 5 gals of water after each job. I hope the Pentaflex will as well.



__________________

 

 

Brett Thompson

Blue Ridge Exterior Cleaning

BlueRidgeExteriorCleaning.com

434-466-1324    540-949-6277

brett@BlueRidgeExteriorCleaning.com



Approved Exterior Cleaner

Status: Offline
Posts: 146
Date:
Permalink  
 

Flojet no longer makes the Penteflex.

AC

__________________
Check Out The Family Of SoftWash Systems  Chemicals On Facebook!